Copper alloy selection for high-current terminals
Start from the temperature-rise limit. Pure copper (C1020, or C10700 where it must stay hard after heating) gives the lowest resistance but little strength. C18140 keeps about 85 % IACS with useful strength and heat resistance. C19400 is the economical choice at 60 %. NB109 at 40 % is used where the terminal itself is the spring.
Candidate grades
| C18140 | C19400 | NB109 | C1020 | C10700 | |
|---|---|---|---|---|---|
| UNS | C18140 | C19400 | C19025 | C10200 | C10700 |
| Equivalents | EN CuCrZr (low-alloyed) | EN CuFe2P / CW107C; JIS C1940; GB QFe2.5 (TFe2.5) | JASO JC400 | EN Cu-OF / CW008A; JIS C1020; GB TU1 / TU2 | EN CuAg0.10(OF) |
| Composition % | Cr 0.15 – 0.45, Zr 0.05 – 0.25, Si 0.005 – 0.05 | Fe 2.1 – 2.6, P 0.015 – 0.15, Zn 0.05 – 0.20, Cu ≥ 97.0 | Ni 1.0, Sn 0.90, P 0.05 | Cu ≥ 99.96, O ≤ 10 ppm | Cu + Ag ≥ 99.95, Ag ≥ 0.085 |
| Conductivity %IACS | 85 | ≥ 60 | 40 | ≥ 100 | ≥ 100 |
| Tensile strength MPa | 393 – 490 | 365 – 550 | 440 – 590 | 195 – 315 | – |
| Tempers | H04, H08 | 1/2H (H02), H (H04), EH (H06), SH (H08), ESH (H10) | 1/2H, H, EH | O, 1/4H, 1/2H, H | – |
| Elastic modulus | 117 GPa | 121 GPa | 130 GPa | 117 GPa | – |
| Density | 8.91 g/cm³ | 8.91 g/cm³ | 8.9 g/cm³ | 8.94 g/cm³ | 8.94 g/cm³ |
Tensile strength is the range across supplied tempers. Full composition, tempers and physical properties are on each grade page.
Typical parts
- Busbars and welded tabs: C1020, C10700
- Blade and pin terminals for battery, charging and power distribution: C18140, C19400
- Female terminals and clips that provide their own contact force: NB109
Notes
Send the current, the allowed temperature rise, the ambient temperature and the terminal cross-section. With those four figures we can narrow the choice to one or two grades.
Questions buyers ask
Why not use pure copper everywhere?
Pure copper is soft and softens further with heat, so it loses clamping and contact force. Alloyed coppers trade a little conductivity for strength that lasts.
Need a recommendation for a specific part?
Tell us the part function, strip thickness and performance targets. We reply within one working day, and sample coils are available for comparative trials.
Material development support