NB109 vs phosphor bronze: terminals that carry current
Choose NB109 when the terminal carries current: at 40 % IACS it conducts about three times better than phosphor bronze, which lowers temperature rise, and it holds contact force better at elevated temperature. Choose phosphor bronze when the current is small and the spring needs more than about 590 MPa.
Side-by-side data
| NB109 | C5191 | C5210 | |
|---|---|---|---|
| UNS | C19025 | C51900 | C52100 |
| Equivalents | JASO JC400 | EN CuSn6 / CW452K; JIS C5191; GB QSn6.5-0.1 | EN CuSn8 / CW453K; JIS C5210; GB QSn8-0.3 |
| Composition % | Ni 1.0, Sn 0.90, P 0.05 | Sn 5.5 – 7.0, P 0.03 – 0.35, Cu + Sn + P ≥ 99.5 | Sn 7.0 – 9.0, P 0.03 – 0.35, Cu + Sn + P ≥ 99.7 |
| Conductivity %IACS | 40 | 13 – 15 | ≈ 12 |
| Tensile strength MPa | 440 – 590 | 315 – 685 | 470 – 885 |
| Tempers | 1/2H, H, EH | O, 1/4H, 1/2H, H, EH | 1/2H, H, EH, SH, ESH |
| Elastic modulus | 130 GPa | 110 GPa | 110 GPa |
| Density | 8.9 g/cm³ | 8.83 g/cm³ | 8.80 g/cm³ |
Tensile strength is the range across supplied tempers. Full composition, tempers and physical properties are on each grade page.
Choose NB109 when
- The part is an automotive or power terminal with a temperature-rise limit
- The terminal works in a warm environment and must keep its normal force
- Strength of 440 to 590 MPa is enough for the design
Choose phosphor bronze when
- The contact is signal level and spring strength is the priority
- Tempers of 600 MPa and above are required
- An existing drawing already specifies C5191 or C5210
Notes
NB109 is a copper-nickel-tin-phosphorus alloy registered as UNS C19025. Its lower strength ceiling is the trade-off for the higher conductivity.
Questions buyers ask
Does switching from phosphor bronze to NB109 reduce temperature rise?
For the same geometry, yes: bulk resistance falls by roughly two thirds. The measured result depends on the contact interface and plating, so confirm it with a temperature-rise test.
Need a recommendation for a specific part?
Tell us the part function, strip thickness and performance targets. We reply within one working day, and sample coils are available for comparative trials.